·Îµå¼¿(Single Point) Model : OBUX Series Á¦Á¶»ç : ºÀ½Å |
|
Á¦Ç°ÀÇ Æ¯Â¡
|
The OBUX series single point load cell is designed for platform scale, hopper scale and automatic check
weighing systems where great accuracy, reliability and
fast measurement are required.
|
|
Model |
OBUX |
OBUT |
Rated capacity (R.C.) |
50,100, 200, 300, 500Kg |
Rated output (R.O.) |
2mV/V ± 10% |
2mV/V ± 0.5% |
Non-linearity |
¡Â0.02% R.O. |
Hysteresis |
Non-repeatability |
Creep error |
¡Â0.03% in 20min. |
Zero balance |
¡Â5% R.O. |
Compensated temperature range |
-10 ~ 70¡É |
Operating temperature range |
-20 ~ 80¡É |
Temp. effect on rated output |
¡Â0.012% LOAD/10¡É |
Temp. effect on zero balance |
¡Â0.04% R.O./10¡É |
Terminal input resistance |
415 Ohms ± 15 Ohms |
Terminal output resistance |
350 Ohms ± 5 Ohms |
Insulation resistance (Min.) |
2000 MOhms at 50V DC |
Excitation connection |
Ø 5mmx1.5m(22AWG x 4Core Shielded) |
Electrial Voltage |
10V(Recommended) /15V(Maximun) |
Protection class |
meets IP 67 |
Safe overload |
150% R.C |
Ultimate overload |
300% R.C |
|
|
|